home page

search

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

GEI sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

 

 

DATA FOR YOUR ENQUIRIES

Please find below all the necessary data for a complete enquiry of a transformer

or fill the form clicking here! you will receive your offer within 24 hours

Rated power (VA)
Number of phase (single phase or three phase)
Frequency (Hz)
Primary winding:

  • Input rated voltage (Vrms)

  • Intermediate taps, if needed (Vrms)

  • If three phase, vector group (delta, wye, or other)

Secondary winding(s):
(All the data are needed for each secondary winding:)

  • Full load output voltage (Vrms)

  • Full load current (Irms)

  • Intermediate taps, if needed (usually current is calculated on the base of the highest output voltage)

  • If three phase, vector group (delta, wye, or other)

Additional information:

  • Full load regulation

  • Isolation voltage

  • Earth screen

  • Intermittance (if lower than 100%)

  • type of terminations (specify type, size, position.)

  • Protection (IP, NEMA classification)

  • Isolation class (I, II, III)

Environment information:

  • Ambient temperature (ºC or ºF)

  • Temperature class (A,B,E,F,H according to IEC standards)

  • Cooling system (natural air –AN-, forced cooling –AF-)

Phisical and mechanical information:

  • Max dimensions (width, depth, height)

  • Pasticular mounting conditions

  • Construction type (open, enclosed, sealed)

  • Special marking requests (logo, hazardous labels)