home page

search

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

GEI sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

 

   

HOSPITAL EARTH LEAKAGE CONTROL SYSTEM ISO-64 range

AUX VOLT. FREQUENCY TOT. MEASURING V. TOT. EMASURING A.
220V a.c. ±20% 50 : 60 Hz < 15V < 0,6 mA

New earth leakage control system suitable for use in medical environment. It applies a continuous voltage between the secondary of the isolation transformer and the earthing point of the system; in case of an earth fault, it mesures the current and consequently the islation resistance of the circuit. ISO64 is the most complete system for the control of IT systems in medical environment. Further to the standard control of the earth leakage required by EN61558-2-15 standard, also controls rhe impedance of the circuit or, first in the market, checks the proper connection of the relay to the system. ISO-64 systems automaticcally checks the connections of the relay reference to the central tap of the secondary transformer and to the earthing (PE) point. If any of these connections is interrupted, the ALARM LED on the front panel immediately flashes. This signal is really essential, as the lack of these connection may result in a bad performance of the system. ISO64 con be combined with the ISO-64R Remote controls to be installed in 503 switch box, and carry a test and sound off botton, mains light, fault light and buzzer.The max number of remote controls connected to each control system is 4. The single phase isolation transformers TMI64 and three phase isolatin transformers TTI64 are compatible with the system.

 MODEL

ISO-64

 Aux. voltage 220V ± 20%
 frequency 50 : 60 Hz
 max consumption 3VA
 total measuring current <0,6mA
 resistive leakage measuing current 0,012 mA
 capacitive leakage measuring current 0,3mA
 internal impedance for resistive measure 1 Mohm
 internal impedance for resistive and capacitive measure < 600 Kohm
 led steps 5000-1000-500-250-50-25 Kohm
 ouutput: 1 Nc-No Relay 5A 250V
 output for remote control Pr1 type MAX 4
 signal circuit voltage < 24V c.c.
 isolation test 2,5kV 60 sec.
 temperature -10°C : +60°C
 warehouse temperature -20°C : +80°C
 relative humidity 90%
 applied standards CEI 64-4-1438 / 64-8-1000
 DIN50022 mounting fast mounting clip on 35MM rail
 dimensions 6 DIN modules 17,5mm.
 