home page

search

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

GEI sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

 

   

SINGLE PHASE SERVO MOTOR VOLTAGE STABILISERS "RA" RANGE

POWER INPUT OUTPUT FREQUENCY SPEED ACCURACY
FROM 500VA TO 3000VA 110 OR 220V ± 15% 110 AND 220V 50/60 Hz 20 mSEC/V ± 2%

 Power  from 500VA to 2000VA
 Input voltage  110 OR 220V a.c. single phase
 Input voltage acceptable variation  from 180V to 240V ot 90V-120V
 Output voltage  110 and 220V
 Output voltage accuracy  ± 3%
 Frequency  50/60Hz
 Regulation speed  WITHIN 0,5sec. against 10% input voltage deviation
 Load tolerable variation  from 0 to 100%
 Acceptable power factor  0 - 1
 Full load efficiency  > 98%
 Harmonic distortion  < 0,5%
 Ambient temperature  0° : 45°C
 Altidude  up to 1000m. without derating
 Standards  IEC 686
 Protections  Fuse protection
 Standard accessories  Illuminated switch, voltmeter, input voltage selector
 cable lead
power part no. dimensions mm. weight
VA A B C kg.
500 RA005 180 170 125 5.0
1000 RA010 195 180 145 8.0
1500 RA015 215 190 180 10.0
2000 RA020 235 230 195 12.0
3000 RA030 250 285 220 15.0
 

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL