home page

search

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

GEI sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

   

SINGLE PHASE MULTI-TAP CONTROL TRANSFORMERS

POWER INPUT OUTPUT FREQUENCY STANDARDS
from 50 to 3000VA

127/220/380/460/480V or
127/220/380/480V or

208/240/277/380/480V

12/24/48V
110/127/220V
50/60 Hz EN 61558-2-1
IEC 989
CEI 96-1
BS 171
 Open type
 Protection IP00
 Isolation class E (Max. Ambient temp.45°C)
 Separate copper windings cl. F-H
 Resin impregnated and tropicalised




SINGLE PHASE CONTROL TRANSFORMERS

   In case you purchase a multi-tap secondary transformer, please follow the table below to get the max. rating available on each secondary voltage:

Secondary 12/24/48V                Secondary 110/127/220V

Sec.V

12V

24V

48V

 

Sec.V

110V

127V

220V

Power

 

 

 

 

Power

 

 

 

50VA

12VA

25VA

50VA

 

50VA

25VA

29VA

50VA

100VA

25VA

50VA

100VA

 

100VA

50VA

58VA

100VA

150VA

37VA

75VA

150VA

 

150VA

75VA

86VA

150VA

200VA

50VA

100VA

200VA

 

200VA

100VA

115VA

200VA

250VA

62VA

125VA

250VA

 

250VA

125VA

144VA

250VA

300VA

75VA

150VA

300VA

 

300VA

150VA

172VA

300VA

400VA

100VA

200VA

400VA

 

400VA

200VA

230VA

400VA

500VA

125VA

250VA

500VA

 

500VA

250VA

288VA

500VA

750VA

187VA

375VA

750VA

 

750VA

375VA

430VA

750VA

1000VA

250VA

500VA

1000VA

 

1000VA

500VA

575VA

1000VA

1500VA

375VA

750VA

1500VA

 

1500VA

750VA

860VA

1500VA

2000VA

500VA

1000VA

2000VA

 

2000VA

1000VA

1150VA

2000VA

2500VA

625VA

1250VA

2500VA

 

2500VA

1250VA

1437VA

2500VA

3000VA

750VA

1500VA

3000VA

 

3000VA

1500VA

1725VA

3000VA

Tables shown are just an example. Ratings can always be calculated according  to these instructions and the voltage indications on the label of the transformer

The label on the transformer shows the highest applicable rating on the secondary side. You can approximately obtain the max. rating for each secondary voltage simply multiplying the voltage by the fuse rating.

e.g.: 500VA transformer sec. 12/24/48V fuse 10A

The max available power on 24V output is: VA= 24(V) x 10 (A) = 240VA

Please note that the max rating is available at the highest primary voltage only. Otherwise you have to derate the transformer according to the primary voltage connected:

e.g.: 500VA transformer Pri: 127/220/380/460V Sec.: 12/24/48V @ 10A

Primary used: 380V Secondary used: 48V

Max rating (VA)= 500VA x ( 380 (V) / 460 (V) ) = 413VA

DOWNLOAD THE PDF VERSION OF THE CATALOGUE

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice